Designed & manufactured in Herefordshire, UK — shipping worldwide Mon–Thu 9–5  |  Fri 9–4  |  +44 (0)1981 241668

Off-Grid Telemetry & Asset Management

Remote Monitoring Solutions for Off-Grid Power Systems

Real-time performance tracking, cloud-based SCADA integration, and predictive maintenance for critical infrastructure worldwide.

Engineered Uptime & Visibility

Power You Can See,
Wherever Your Assets Operating.

Unattended off-grid infrastructure requires total visibility. Leading Edge Power delivers industrial remote monitoring packages engineered to track wind generation, solar input, battery health, and generator status across harsh global environments.

Real-Time Telemetry

Continuous monitoring of voltage, current, power output (W), and energy production (kWh) across all generation sources.

  • Live generation metrics
  • Instantaneous load draw
  • Cellular & Satellite connectivity

Historical Analytics

Analyze performance trends over time to optimize battery usage, load cycles, and future renewable system expansions.

  • Multi-year historical logging
  • Exportable report data
  • Seasonal resource tracking

Battery & SoC Care

Accurate monitoring of deep-cycle AGM, Gel, or Lithium battery State of Charge (SoC) and cell temperature.

  • State-of-charge calculation
  • Low SoC warning alerts
  • Thermal protection telemetry

Victron Integration

Native integration with Victron Cerbo GX and VRM (Victron Remote Management) portal for intuitive dashboard control.

  • Unified wind & solar dashboard
  • Remote firmware updates
  • Custom alarm thresholds

Industrial Telemetry Platform

Proactive Remote Asset Management Made Simple.

Designed for offshore communications platforms, national utility monitoring, remote telecom towers, and environmental sensing masts where unplanned downtime causes catastrophic failure.

CAPABILITY 01

Integrated Multi-Source Tracking

Monitor small horizontal and vertical axis wind turbines, monocrystalline solar arrays, fuel cells, and back-up diesel generators on a single unified interface. Eliminate fragmented monitoring systems.

CAPABILITY 02

Early Warning Alarm Triggering

Configure automated SMS, email, or webhook notifications for low battery voltage, unexpected load spikes, or fuel depletion. Resolve maintenance triggers before power loss occurs.

CAPABILITY 03

Remote Parameter Configuration

Adjust charge controller profiles, relay triggers, and load-shedding parameters remotely without sending field technicians or chartering offshore service vessels.

System Specifications & Compatibility

Feature Specification / Standard Application Benefit
Hardware Gateway Victron Cerbo GX / GlobalLink 520 / Custom Industrial Telemetry Enclosures Ruggedized, low-power processing built for extreme environmental enclosures.
Supported Protocols Modbus TCP/RTU, VE.Direct, VE.Can, MQTT, SNMP v2c/v3 Direct integration into client SCADA, PLC, and Network Operations Centers (NOC).
Connectivity Options Global 4G/LTE Cellular, Starlink Satellite, Iridium Telemetry, Ethernet, Wi-Fi Reliable communication pathways regardless of site remoteness or geography.
Operating Temperature -20°C to +50°C (-40°C to +70°C optional extreme pack) Proven reliability from polar scientific stations to desert telecom masts.
Power Consumption Ultra-low background draw (< 2.5 W continuous) Minimizes parasitic load on winter off-grid battery reserves.

Enterprise ROI

Why Global Operators Specify Our Monitoring.

Remote monitoring turns unpredictable environmental power into a predictable, managed industrial asset.

Drastic O&M Cost Reduction

By accurately diagnosing fault conditions remotely, maintenance personnel arrive on site with the exact replacement components required, eliminating exploratory field trips.

Guaranteed Infrastructure Uptime

Continuous tracking of battery State of Health (SoH) allows proactive battery replacement cycles years before sudden power failure impacts critical communications.

Data-Driven Resource Sizing

Analyze empirical wind speed and solar irradiance metrics over multi-season cycles to accurately size equipment upgrades for future site expansion.

Technical Support & Guidance

Frequently Asked Telemetry Questions.

Our monitoring architectures connect onsite power controllers (such as the Victron Cerbo GX) to global communication networks using multi-band 4G/LTE cellular routers, Starlink satellite terminals, or Iridium telemetry modems. Data is securely updated to cloud management portals 24 hours a day.

Yes. In addition to cloud portals, our gateways support Modbus TCP/RTU, MQTT, and SNMP protocols, enabling direct data polling by your central control room software or Network Operations Center without third-party dependencies.

The system monitors instantaneous and cumulative wind turbine power output (W, kWh, V, A), solar generation, battery bank State of Charge (SoC percentage and voltage), system temperatures, load draw, and automatic methanol fuel cell or diesel generator run hours and fuel levels.

Offshore and remote mountain sites carry significant logistical costs for service personnel. Remote telemetry alerts engineers to impending issues—such as low fuel or degrading battery cells—before failure occurs, allowing maintenance to be scheduled efficiently during routine service windows.

Take Control of Your Off-Grid Assets.

Specify custom telemetry packages tailored to your continuous load profile, communication protocols, and environmental site requirements.